G10-3052 Replacement UV Lamp 185NM

| Our Part #: | G10-3052 |
| Length: | 14.06" or 357 mm ± 3mm (not including pins) |
| Base Type: | Single Pin each end |
| Lamp Type: | Standard Output |
| Wavelength: | 185NM |
| Glass Type: | VH (Ozone) |
| Base Color / Material: | White Ceramic Base |
| Bulb Diameter: | 15mm |
| Lamp Voltage*: | 55V |
| Lamp Wattage*: | 16W |
| Operating Current*: | 360mA |
| Rated Life (hrs)**: | 12000 |
| Replaces/Fits Models: | American Ultraviolet GML070, Aquafine 3052, Aqua Azul L-8-120, Atlantic UV 05-1347, Siemens/Sunlight LP4175, W2T365343, W2T174452, UDC 7008-248, Wedeco/Ideal Horizons LMP11006, CI-1SS, IH-1SS, First Light 3053 |
|
*Operating Current, voltage, wattage disclaimer — Lamps are measured after 100 hours of operation under lab conditions. These values are subject to wide variations under application/field conditions. **Rated Life — Rated life is for reference purposes only and is based on a group of lamps operating under lab conditions. Actual life depends on the operating conditions of the lamp. |
|